A. Before each startup, lubricating oil must be added to each moving component once.
B. Before production, check whether all moving parts are secure, whether screws are loose or detached, and whether the belt transmission part is abnormal.
C. Check if the high-pressure air source, low-pressure air source, power supply, and water source are normal.
D. Check whether the emergency stop switches, safety door switches, and protective device detection switches are normal.
F. Check if the lamp tube is damaged or broken.
G. Check if the pneumatic components are leaking and if the action is sensitive.
H. Check if the triplet has abnormal air leakage, is it blocked, and if the water storage capacity of the water cup is too full
I. When starting the machine, the motor must be started first, and the heating machine must be started with a delay of 30 seconds to prevent voltage fluctuations.
J. The internal hygiene of the filling machine must be cleaned.
K. When the machine is running, it is necessary to pay close attention to whether there is any abnormal noise, and to detect it early, stop it in a timely manner, and solve it in a timely manner.
L. In case of emergency shutdown due to safety protection, the cause must be analyzed based on the on-site situation, and the problem must be found and resolved before starting the machine.